194 visiting now: 181 USA USA flag 4 Singapore Singapore flag 3 Brazil Brazil flag 2 UK UK flag 2 India India flag 2 France France flag 1 Germany Germany flag 1 Belgium Belgium flag 1 Hong Kong Hong Kong flag 1 China China flag 1 Finland Finland flag 1 Sweden Sweden flag 1 Argentina Argentina flag

Highlighted Companies

  • Eagle Eyes China Inspection Company (China): Eagle Eyes (CHINA) Quality Inspection Co.,Ltd. is a professional Third... https://www.china-qualityinspection.com
  • YESN-China shipping Labels manufacturer-compatible label factory (China): XIAMEN YESN-China shipping Labels manufacturer-compatible... http://www.yesnlabels.com
  • E6000 Handheld Power Quality Analyzer - China

    price: contact company for price

    Features

    Troubleshoot real-time: Analyze the trends using the cursors and zoom tools-even while background recording continues.

    Automatic Transient Mode: Capture 200 kHz waveform data on all phases simultaneously up to 6 kV

    Measure all three phases and neutral: With included four current probes

    System-Monitor: Up to ten power quality parameters on one screen according to EN50160 power quality standard

    View graphs and generate reports: With included analysis software

    Logger function: Configure for any test condition with memory for over 400 parameters at user defined intervals.

    Mains signaling: Measure interference from ripple control signals at specific frequencies

    Inrush mode: For troubleshooting nuisance circuit breaker tripping.

    AutoTrend: Every measurement you see is always automatically recorded, without any setup.

    Fully Class-A compliant: Conduct tests according to the stringent international IEC 61000-4-30 Class-A standard.

    Battery Life: Seven hours operating time per charge on NiMH battery pack

    High safety rating: 600 V CAT IV/1000 V CAT III rated for use at the service entrance

    • Comparing to online power quality analyzer, E6000 handheld type with small size, light weight, easy for the engineer to carry and carry out to survey work whenever and wherever.

    • Easy to wiring

    • It can operate directly to the line under test under the circumstances that the Power Grid without interrupt.

    • Multi-range current switching

    • based on actual demand, the different range of current clamp can be replaced to improve measurement accuracy.

    Applications

    Frontline troubleshooting - quickly diagnose problems on-screen to get your operation back online

    Predictive maintenance - detect and prevent power quality issues before they cause downtime

    Quality of service compliance - validate incoming power quality at the service entrance

    Long-term analysis - uncover hard-to-find or intermittent issues

    Load studies - verify electrical system capacity before adding loads

    Energy assessments - quantify energy consumption before and after improvements to justify energy saving devices.

    Specifications

    Measurement Items

    Be measured Type of measurement

    RMS Voltage Voltage

    RMS Current Current

    Frequency Deviation Frequency

    Three-phase Unblanced Voltage, Current

    Voltage fluctuations Voltage

    Flicker Voltage

    Harmonics and inter-harmonics, higher harmonic Voltage, current

    Power Active, reactive, apparent power factor

    Event log Transient pulse, the voltage rise, voltage sags, voltage interruption, the impact of current, frequency of abnormal

    Input parameter

    Measuring circuit 1P2W, 1P3W, 3P3W, 3P4W

    The fundamental frequency of the measuring circuit 50Hz/60Hz

    Number of input channels Voltage, current, 4

    Measurement range Voltage Measurement Range: Nominal value: 100V, 230V, 400V, maximum 1000V

    Current measurement range: Depending on the current clamp, current clamp the output voltage signal, the maximum voltage: 10V peak

    Environmental security parameters

    Use of the environment 0 ° C to +45 ° C, humidity 90rh%

    Storage environment -20 ° C to +50 ° C, 95RH% humidity (non-condensing)

    Power input voltage +100VAC ~ +240VAC

    Electromagnetic Compatibility Level 3: GB / T 17626.2-2006 Electrostatic Discharge Immunity

    Level 3: GB / T 17626.3-2006 RF electromagnetic radiation the Immunity

    Level 3: GB / T 17626.4-2008 electrical fast transient burst immunity

    Level3: GB / T 17626.5-2008 surge (impact) Immunity

    Level 3: GB / T 17626.8-2006 frequency magnetic field immunity

    Level 3: GB / T 17626.9-1998 Pulse magnetic field immunity

    Level 3: GB / T 17626.12 -1998 Oscillatory waves immunity

    Environmental reliability GB/T 2423.1-2008 low temperature

    GB/T 2423.2-2008 high temperature

    GB/T 2423.4-2008 alternating hot and humid

    GB/T 2423.5-1995 impact

    GB/T 2423.10-2008 vibration

    GB/T 2423.22-2002 temperature changes

    Dustproof, waterproof IP20(GB 4208-93/IEC 529: 1989)

    Security 500V/10M, 2KV: GB/T 15479-1995

    External interface parameters

    USB Device 1 The upload power quality data

    TF card to expand storage 1 Built-in capacity Optional, up to 8G

    Battery 1 4500mAh Ni-MH battery

    LCD 1 26 million color 5.6-inch LCD screen with a resolution of 640 * 480

    Voltage and current measurement interface 8 Test voltage and current input port

    Frequency

    Measurement method 10 waveform (50Hz) the calculated frequency

    Display Display of a channel frequency value

    Measuring range / resolution 50.0000Hz/0.0001Hz

    Measurement bandwidth 42.5000~57.5000Hz

    Measurement accuracy ±0.001Hz

    1/2 rms voltage 1/2 rms, current

    Measurement method Once every two cycle operations, a waveform operations per cycle to take 1/2 cycle

    Sampling Frequency 200K

    Measuring range / resolution 120V/0.01, 230V/0.01, 400V/0.01, Based on the use of current clamp

    Measurement accuracy 0.1% of the nominal voltage

    RMS voltage

    Measurement method 10 waveforms (50Hz) the operator

    Display Per channel RMS voltage

    Sampling Frequency 200K

    Measuring range / resolution 120V/0.01, 230V/0.01, 400V/0.01

    Display Current per channel RMS

    Measuring range / resolution Based on the use of current clamp

    Harmonic voltage, harmonic current

    Measurement method According to IEC61000-4-7, the magnitude of the analysis window 10 cycles

    Window points Every 10 cycles of 5120 points

    Display Histograms, tables

    Sampling Frequency 200KHz

    Number of measurements 0~50

    Measurement accuracy voltage harmonics greater than 1% of the nominal value: Error is less than 1% rdg

    voltage harmonics less than 1% of the nominal value: Error is less than 0.05% rdg

    the nominal voltage current harmonics greater than 3% of the nominal value: the error is less than 1% edg

    current harmonics is less than 3% of the nominal value: Error is less than 0.05% of the nominal voltage

    interharmonic voltage interharmonic current

    Display Form

    Number of measurements 1~16

    High harmonic voltage, high harmonic currents

    Measurement method Every 10 cycles of 5120 points

    Number of measurements 1 to 35 group

    Active power, reactive power, apparent power

    Measurement method Active power: 10 cycles computing

    Apparent power: Valid values of voltage and current operations

    Reactive Power: apparent power, active power is calculated

    Display Real-time data display

    Measuring range / resolution Determined based on the voltage and current range

    Measurement accuracy ±0.5%rdg

    Power Factor

    Measurement method Rms, current rms voltage, active power is calculated

    Measuring range / resolution -1.0000~1.0000

    Measurement accuracy ±1%rdg

    Voltage unbalance, current unbalance (negative and zero sequence)

    Measurement method when 3-phase 3-wire or 3-phase 4-wire, calculate by three-phase fundamental ingredients

    Display Voltage unbalance

    current imbalance

    Measuring range 0.00%~100%

    Measurement accuracy Voltage unbalance: ± 0.5%

    Current imbalance: ± 0.5%

    Voltage fluctuations

    Measurement method Half-wave to calculate the mean square

    Display The fluctuation trends, real-time values of voltage fluctuation

    Measurement accuracy ±1%

    IEC Flicker

    Measurement Item The short flicker (PST), long flicker (Plt)

    Measurement method According to IEC61000-4-15 10 minutes PST continuous measurement, continuous measurement and calculation 2 hours Plt

    Display The flicker trends, Pst value, Plt

    Measuring range 0~20

    Measurement accuracy ±5%

    The impact of current

    Measurement method Half-wave rms current exceeds the set value of the positive impact of current

    Display The impact of current waveform, the impact of the current maximum

    Measurement accuracy 0.10%

    Measurement method Temporary swell: half-wave rms voltage positive direction exceeds a set value, it is determine as Temporary swell

    temporary sag: Valid values are negative direction exceeds a set value, determine as temporary sag

    Short interruptions: half-wave RMS voltage exceeds the set value in the negative direction, the decision for an instant interrupt

    Display Temporary swell, sag, short interruptions waveform duration, amplitude etc.


    Company Contact:


    • Phone: 861085782698

    • Address: 01117-8 Fortune Street No.67 Chaoyang Road, Chaoya, Beijing , China

    • Email: Email


    Published date: July 3, 2013

    • Business Description: involved in international trade import export of goods, products, and services

    Related listings



    • Laer Enginetachometer Ged 2600
      Laer Enginetachometer Ged 2600
      Equipment - Testing / Measuring - guangzhou landtek isntruments - China - June 19, 2013 - contact company for price

      Application: 2 in 1 (Engine & Laser tachometer ) Applicable to the product departments of motor, fan, paper-product, plastics, chemical fiber, washing-machine, automobile, airplane, steamer etc. Model: GED2600 Application: 2-CIRCLE 1, 2, 3, 4-cylinde...

    • Digital Lux Meter Lx 9626
      Digital Lux Meter Lx 9626
      Equipment - Testing / Measuring - guangzhou landtek isntruments - China - June 19, 2013 - contact company for price

      Application: widely used in electro-optical sources, research teaching, metallurgy building, industry insp-ection as well as agriculture researching and illumination control. Model: LX9626 Measuring range:0-50000LUX 0-5000FC 3 RANGE: x1, x10, x100 re...

    • Dew Point Meter Ht 6292
      Dew Point Meter Ht 6292
      Equipment - Testing / Measuring - guangzhou landtek isntruments - China - June 19, 2013 - contact company for price

      Application: widely used in workshops, offices, plants, libraries, computer stations, laboratories and warehouses Model: HT6292 DEW POINT METER Measuring range: dew point –40-40℃ humidity 0-100%RH TEMP -10-65℃ Accuracy: dew point ±0.5T...



    Safe Trade Tips

    • Ask for business references and check them
    • Use a payment method that offers better protection for all such as Letters of credit and verified professional escrow services. Avoid payments in advance such as money transfers
    • Verify their business via their local Chamber of Commerce
    • Search the internet using their website address, their business name, their phone and fax numbers, and their email addresses to see if you can find any feedback about them.
    • Get to know more about scams and fraud to avoid: Internet Crime Complaint Center - Consumer Financial Protection Bureau
    • This site is never involved in any transaction, and does not handle payments, shipping, guarantee transactions, provide escrow services, or offer "buyer protection" or "seller certification"