    Wanlida Static Synchronous Compensator (STATCOM/SVG)

    Main Functions

    Improve the stability of power transmission

    In long distance transmission system, Static synchronous compensator (STATCOM/SVG) can not only compensate the power line losses caused byreactive power, increase line voltage and improve effective transmission capacity under normal operation, but also offer reactive power adjustment in time, damp system oscillation and improve system stability incase of fault.

    Maintain the receiving-end voltage level

    Since high capacity load centers lack reactive power support, it is easy to cause grid voltage dip, evencause voltage collapse.

    However, Static synchronous compensator (STATCOM/SVG) is capable of fast var adjustment.

    Therefore, the receiving-endvoltage level is greatly stabilized.

    Reactive power compensation leading to high power factor and low line losses

    Many types of loads need a mass of reactive power when operation, such as asynchronous motors, arcfurnaces, rolling mills and high rating rectifiers.

    At the same time, the upstream transformer and lineimpedance also generate reactive power, which still leading to low power factor.

    For the power system, loads with lower power factor will increase the line losses, voltage drop anddeterioratevoltage quality.

    Additionally, reactive power will reduce efficiency of power generation, transmission and distribution.

    For clients, low power factor will increase production costs.

    Restrain voltage fluctuation and flicker.

    Voltage fluctuation and flicker are mainly caused by rapid loads variation.

    This rapid variation also causesthe load current fluctuation dramatically.

    The current variation leads to system voltage losses changingvery fast, which brings the receiving-end grid voltage flicker.

    The typical loads that cause voltage flicker arearc furnaces, rolling mills, electric locomotives, etc.

    Static synchronous compensator (STATCOM/SVG) can offer fast reactive power regulation, which mitigate voltage fluctuation and flicker easily caused byloads variation.

    Now, Static synchronous compensator (STATCOM/SVG) is the best solution to restrain voltage fluctuation and flicker compared with MCR, TCR etc.

    Mitigate 3-phase unbalance.

    In distribution network, there are a lot of 3-phase unbalance loads, typically like electric locomotives and arcfurnaces.

    At the same time, line and transformer impedance unbalances can also cause voltage unbalanceproblem.

    Static synchronous compensator (STATCOM/SVG) can fast compensate negative sequence current caused by unbalance loads, which ensurebalanced 3-phase grid current.

    Thus, it improves the power supply quality greatly.

    Eliminate harmonics including Even-order, Odd-order, subharmonic and inter-harmonics(Option)

    Static synchronous compensator (STATCOM/SVG) has very good harmonic suppression functions including even-order harmonic, odd-order harmonic, subharmonic and inter-harmonics, it adopted Instantaneous power theory to detect and calculate harmonic current automatically and then control PWM converter, and input compensated current into power grid which is of the right magnitude with harmonic current, but with inverse polarity.

    Structure of Wanlida Static Synchronous Compensator (STATCOM/SVG)

    It mainly consists of reactor, start-up cabinet, cascade multilevel inverters cabinet and control cabinet.

    Technical Advantages

    Static Synchronous Compensator (STATCOM/SVG) has the following advantages compared with traditional compensation methods:

    Faster response speed

    STATCOM response time: ≤5ms

    Traditional static compensator response time: ≥10ms.

    STATCOM can finish the conversion from rated capacitance var to rated inductance var in a very short time.

    This unexampled response speed makes STATCOM very suitable for impact load compensation.

    Stronger voltage flicker restrain capability

    SVC can restrain voltage flicker to 2: 1 in maximum, but STATCOM can achieve 5: 1, even higher.

    SVC cannot improve its capability for voltage flicker mitigation even with high capacity because of low response speed.

    But STATCOM responds fast.

    When its

    capacity is increased, the capability of voltage flicker mitigation can be further improved.

    Wide operation range

    STATCOM can work from rated inductive power to rated capacitive power.

    So compared with SVC, STATCOM operation range is much wider.

    Furthermore, STATCOM can output rated reactive current even under low system voltage.

    Multiple compensation function

    STATCOM is not only functioned as fast reactive power compensator, but also harmonics and unbalance compensator according

    to different demands of different clients.

    Low harmonic content

    STATCOM utilizes PWM, 3-level and multiple technologies.

    Therefore, it generates very low harmonics with compensating load

    harmonics at the same time.

    Thus, STATCOM becomes a true multifunctional compensator.

    Small volume

    HV big capacitors and reactors are not necessary.

    STATCOM installation area is greatly smaller than that of the same capacity SVC, only 50% or even lower.

    At the same time, Wanlida cooperates with the No.

    1 Science university in China-Tsinghua University to develop SVG, but the most important advantage for Wanlida is that we have many years experiences for Medium voltage variable frequency drives technology, because the Static Var Generator has almost structure and technology with Medium voltage variable frequency drives, in addition, Wanlida has over 21 years experiences for protection relays for reactor, capacitor etc.

    Technical Features

    Provides fast smooth dynamic compensation from inductive to capacitive in reactive power, also eradicates reactive power delivery to power grid, it can meet the maximum request to compensate power factor and keep power factor close to 1.0 anytime.

    Low power loss, more better economical operation.

    Has powerful capability to support voltage and ability to continuously operate under the 1.1 times of overload.

    More fast response time and better effect for restraining flicker.

    Produce no harmonic and and compensate nearly all load harmonics without amplifying them and without generating harmonic resonance, it has more safety, stability and reliability because it is not sensitive to the system power parameters.

    Modular design.

    All power units are thesame in structure and electric performance, thus they are interchangeable, which is easy for installation and maintenance.

    Redundant N+1 structure provides more higher reliability.

    Less space for installation.

    Technical Specifications

    Rated voltage

    6kV/10kV/22kV/27.5kV/35kV

    Rated Frequency

    50Hz (±2%)

    Rated reactive output

    Capable of continuous output that ranges from inductive rated reactive to capacitive rated reactive

    Connection mode

    3phase3wires Star connection

    Response Time

    ≤5ms

    Active-power loss

    ≤2% of rated power

    Overload capacity

    Capable of continuous operation at 1.1 times overload

    Harmonic characteristics

    When it only compensates reactive power output, THDU <3%, THDI <4%; harmonic suppression rate when harmonic wave harnessing >85%

    Allowable unequalization degree of voltage

    The permissible value of unbalance degree of connection-point system voltage shall not exceed 60%

    Operation indication

    Touch screen, full-digitalized control

    Protection function

    Power grid overvoltage, undervoltage, voltage imbalance; overload, inverter over/undervoltage, overcurrent , overtemperature; capable of automatic exiting from the power grid in case of a equipment failure

    Communication modes

    Ethernet; capable of background-computer remote monitoring; reserved with RS485/232 interface

    Cooling system

    Forced air cooling

    Factory Acceptance Test

    We built the first-class high voltage and big capacity power electronic equipments test platform to realize Factory Acceptance Testing for whole machine before delivery.


    Company Contact:


    • Phone: 867563395623

    • Address: Wanlida Relay Protection Industrial Park, No. 1 Te, Zhuhai , China

    • Email: Email


    Published date: August 22, 2013

    • Business Description: Incorporated in 1991, Zhuhai Wanlida Electric Co., Ltd. (www.

      zhwld.

      com)

      ('the Company'), is located in Relay Protection Industrial Park, No.

      1

      Technology Road, Science and Technology Innovation Coast, High tech

      Zone, Zhuhai City, coving a land area of approximately 60 thousand

      square meters (including Park 1 and Park2).

      The Company was listed for

      equity financing on November 13, 2007 (equity securities abbreviated as:

      Wanlida stock certificates, code: 002180), with a registered capital of

      124, 980, 000 Yuan.

      The Company keeps on her aggressive 'production,

      study, research and application' co operation with the famous academies

      such as Tsinghua University, Chinese Academy of Sciences and Central

      China University of Science and Technology and carries out relevant

      technology innovation.

      It is a national high tech enterprise that deals

      with specialized development, production and sales of substation

      integrated automation systems and Medium voltage variable frequency

      drives, Medium voltage magnetically controlled soft starters, Static

      synchronous compensator(STATCOM/SVG), Static VAR compensator(SVC),

      Active power filter(APF/AHF), Thyristor switched capacitor bank

      (TSC/TSF), High voltage direct current light transmission systems etc

      power electronic equipments.

      In addition, the Company is known as a

      famous manufacturer and backbone enterprise of transformer substation

      integrated automation and power electronic equipments fields in China,

      and it also acts as fresh blood in the field of energy conservation and

      emission reduction.

      Wanlida passed the ISO9001 quality system certification, ISO14001 Environment Management System Certification and OHSMS18001 Occupation Health &Safety Management System Certification; All products passed the test of sated authoritative inspection bureau.

      And it had been rated as 'National High and New Technology Enterprise', 'Enterprise Recommended by State Economic and Trade Commission for Reconstruction of Urban and Rural Electric Grids', 'Key Software Enterprise Covered by National Program', 'Excellent enterprise of China', 'First choice Manufacturer for Electric Framework Protocol Sponsored by CNPC', 'Excellent Enterprise of Guangdong Province', 'Optimum Good faith Enterprise of Guangdong Province', 'Contract honoring Enterprise of Guangdong Province', 'Top 10 Private Enterprises of Zhuhai City', and 'Enterprise with Grade AAA Bank Credit '.

      Wanlida has a very strong R&D teamwork which has a population of over 100 with doctor's degree, postgraduate degree and bachelor's degree etc, and all of the products are designed strictly according to IEC standards; Wanlida has modern standard workshops, it brought advanced SMT production lines and wave soldering machines into company from abroad, and built the first class high voltage and big capacity power electronic equipments assembling and test platform, which is able to realize full load test and ensure that all of products have exquisite technics and reliable quality; At present, Wanlida covers all of domestic areas except Hongkong, Macau and Taiwan, and it also sells the products to Southeast Asia, Middle East, South America, Africa etc over 20 countries.

      The Company aims to grow into the most dedicated electric automation enterprise in the world, and commits itself to building the aircraft carrier of power electronic energy efficiency products.

    Related listings



    • 5kw Vertical Axis Wind Turbine Generator
      5kw Vertical Axis Wind Turbine Generator
      Generators - Jilin Powerfil Renewable Energy Technology Co.,Ltd - China - June 1, 2013 - contact company for price

      FDC-1KW-H vertical axis wind turbine Applications: 1.residential, 2.hotel, 3.hybrid street light, etc… Specification: R ated Power: 5KVA Rated wind speed: 22.4mph(10m/sec) Start-up Wind Speed: 6.7mph(3.0m/sec) Cut in Wind Speed: 8.95mph(4.0m/sec) Sur...

    • High Efficiency Stable Wind Turbine
      High Efficiency Stable Wind Turbine
      Generators - Jilin Powerfil Renewable Energy Technology Co.,Ltd - China - June 1, 2013 - contact company for price

      FDC-1KW-H vertical axis wind turbine Applications: 1.residential, 2.hotel, 3.hybrid street light, etc… Advantage: 1.FDC H series items are designed according to triangle form construction truss structure, this makes the wind turbine rather stable and...

    • Magnetic Bearings Wind Turbine
      Magnetic Bearings Wind Turbine
      Generators - Jilin Powerfil Renewable Energy Technology Co.,Ltd - China - June 1, 2013 - contact company for price

      FDC-3KW-H vertical axis wind turbine Advantage: 1.FD CH series items are designed according to triangle form construction truss structure, this makes the wind turbine rather stable and firm during operation. 2.The wind force will mainly press on the ...



    Safe Trade Tips

    • Ask for business references and check them
    • Use a payment method that offers better protection for all such as Letters of credit and verified professional escrow services. Avoid payments in advance such as money transfers
    • Verify their business via their local Chamber of Commerce
    • Search the internet using their website address, their business name, their phone and fax numbers, and their email addresses to see if you can find any feedback about them.
    • Get to know more about scams and fraud to avoid: Internet Crime Complaint Center - Consumer Financial Protection Bureau
    • This site is never involved in any transaction, and does not handle payments, shipping, guarantee transactions, provide escrow services, or offer "buyer protection" or "seller certification"